SSI Encoder Part No: RM44SC0013B10F2E10
Observation
There's a repeat of data transmission, according to the timing diagram there will be a tm of at least 12.5us but 12.5us is longer than the one transfer window, with closer analysis the data seems to be 1.5us apart
SSI Timing Diagram
Low Frequency Testing
Received Data: 10001011100100 1000101110....
4MHz Testing